| PARAMETER | SPECIFICATION |
| Display | 12.1’’ TFT screen |
| ECG | • 5 Leads: RA, LA, LL, RL,V
• Lead mode: I, II, III, AVR, AVL, AVF, V • Gain: x1.25mm/mV,2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV (error 5%) • Sweep speed: 6.25mm/s,12.5mm/s,25mm/s, 50mm/s (errors±10%) • Bandwidth: Surgery 1~25 Hz, Monitor 0.5~40 Hz, Diagnostic 0.05~130 Hz • Sensitivity: >200 V P-P, CMRR≥ 112dB • Differential Input Impedance: >5M, ohm Electrode Offset Potential ±300mV • Polarization Voltage >±500mV • Input Impedance >5 M • Calibration Voltage: 1mV± 5% |
| SpO2 | • Measurement range: 0 ~ 100%
• Resolution: 1% • Precision: 70% ~ 100%±2% 0% ~ 69%: no definition given |
| Pulse Rate | • Measure/alarm range: 20 ~ 300bpm
• Resolution: 1bpm • Accuracy +3bpm |
| NIBP | • Method: Oscillometry
• Measure mode: Manual, Auto, STAT • Measure interval in auto mode:1~5 / 10 / 15 / 30 / 60 / 90 / 120 / 180 / 240 / 480min • Measure period in STAT mode: 5min • Pulse rate range: 40 ~ 240bpm • Measure & alarm range: Adult: SYS 40 ~ 280mmHg DIA 10 ~ 220mmHg MEAN 20 ~ 240mmHg Pediatric: SYS 40 ~ 220mmHg DIA 10 ~ 160mmHg MEAN 20 ~ 170mmHg Neonatal: SYS 40 ~ 135mmHg DIA 10 ~ 100mmHg MEAN 20 ~ 110mmHg • Static pressure measurement Range:0 ~ 300mmHg • Accuracy 3mmHg • Resolution: 1mmHg Accuracy: Max. Mean Error 5mmHg • Max. Standard Deviation: 8mmHg • Overpressure protection: Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg |
| RESP | • Method: impedance between RA-LL
• Resp Impedance range: 0.3 ~ 3 • Base Impedance range: 200 ~ 4000 • Bandwidth:0.3 ~ 2.5Hz • Gain: × 0.25, × 0.5, × 1, × 2, × 4 • Resp rate: Measurement Range Adult: 0 ~ 120BrPM Neonatal/Pediatric 0 ~ 150BrPM • Resolution: 1BrPM • Accuracy: 7 ~ 150BrPM (2BrPM), 0 ~ 6BrPM (unspecified) • Apnea Alarm: 10 ~ 40s |
| TEMP | • Channel 2
• Measure & alarm range: 0 ~ 50℃ • Resolution: 0.1℃ • Accuracy (no sensor) ±0.1℃ (0 ~ 50℃) (excluding sensor error) |
| ST Segment | • ST Segment Range: -2.0mV ~ +2.0mV
• Accuracy: Ranging -0.8 mV ~ +0.8mV, measuring error is ±0.02mV or ±10%, The larger prevails. • No definition for other ranges. |
| Data Storage | • Trend diagram/table: 720h
• NIBP review: 10000 events • Wave review: 12h • Alarm review: 200 alarm events • Support drug concentration titration analysis |
| Power Requirements | • AC: 100~ 240V,50Hz/60Hz
• DC: Built-in rechargeable battery • Battery: 11.1V 24wh Li-ion battery • 2h operating after full charge • 5min operating after low battery alarm |
| Operating environment | • Temperature: 0 ~ 40℃
• Humidity: 15% ~ 80% • Pressure: 86.0 kPa ~ 106.0kPa |
| Transport and Storage
Environment |
• Temperature: -20 ~ 55℃
• Humidity: 10% ~ 90% • Pressure: 86.0 kPa ~ 106.0kPa |
| Application Range | • Adult/Pediatric/Neonatal (Necllor SpO2 & Suntch NIBP) / Surgery / • Operating Room / ICU / CCU (Separated parameter board) |
| Dimension and Weight | • Equipment: 305*162*290mm, 4kg
• Package: 380*350*300m, 4.5kg |
ECG Cable & Electrodes
SpO2 Sensor
TEMP Probe
NIBP Cuff & Tube
Power Cord
Lithium-ion Battery
User Manual
Touch Screen, Etco2, Dual IBP, Nellcor Spo2, Suntch NIBP, Recorder, Trolley/Wall Mount Bracket