-10.4” high-resolution color touch screen
-User friendly design interface
-Tidal volume 5~1500 ml
-Up to 5 flow tubes for 3 gases
-PSU material of breathing circuit
-By-pass Tech for soda lime canister,Soda lime can be replaced during surgery
-All ventilation modes to satisfy neonate, pediatric and adult patients
-Integrated breathing circuit with built-in heater
-Highly visible ACGO
| PARAMETER | SPECIFICATION | |
| Screen | 10.4” high-resolution color touch screen, 1024×768 pixels | |
| Gas supply | O2, N2O, AIR | |
| Flow Meter | O2: 0–10L/min
N20: 0–10L/min Air: 0–10L/min |
|
| Selectatec bar | Dual positions | |
| Mechanical Flowmeter | 5 flow tubes for 3 gases | |
| Rapid Oxygen Flow | 25–75L/min | |
| Waveforms | Up to 3 waveforms, user configurable | |
| O2 -N2O Link System | Type: Gear wheel linkage;
Range: O2 concentration not lower than 25%. |
|
| Low Oxygen Pressure Alarm | There will be sound alarm when the oxygen pressure
<0.22MPa±0.022Mpa |
|
| Respiratory Circuit | Working mode: all-close, semi-close, semi-open;
APL: 1-70 cmH2O |
|
| Respiratory Bellows | Bellows for adults, tidal volume range:0–1500ml;
Bellows for children, tidal volume range:0-300ml. Anyone can be chosen for application as required by the customer |
|
| VENTILATOR | ||
| Ventilation Mode | Manual, VCV, PCV, SIMV-VC, SIMV- PC, PSV, Standby, ACGO
Optional modes: PRVC, HLM |
|
| Ventilation Function | PEEP, SIGH, IP, IRV, standby | |
| Spirometry loop | P-V, P-F, F-V, reference Loop | |
| Ventilation Parameters | Tidal volume 5~1500ml
Rate 4~100bpm SIMV rate 4~40bpm I:E 4:1~1:8 Inspiratory trigger pressure OFF, PEEP-20 ~ PEEP-1cmH2O PEEP (control parameter range) OFF, 4cmH2O~30cmH2O PEEP (monitoring parameter range) 0 cmH2O~70cmH2O Pressure limitation 10~100cmH2O Platform -20~120cmH2O Pressure control 5~70cmH2O Pressure slope 0~2 s |
|
| Parameters for Ventilation
Monitoring |
Expired tidal volume, Inhale tidal volume, Minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, PEEP, inspiratory trigger pressure, Inspiratory platform, oxygen concentration, battery capacity, pressure-time waveform, flow-rate-time waveform, volume-time waveform, flow-volume loop, pressure-volume loop | |
| Sustained High-pressure
Alarm |
Paw greater than alarm limit for continuous high airway pressure for >15s | |
| Auxiliary power outlets | 3 | |
| Wheels | Four wheels(155mm) with 2 or 4 separate brakes | |
| Drawers | 2 | |
| Vaporizer | It has the function of automatic compensation based on pressure, temperature, and flow rate.
The regulation range of evaporator concentration is 0-6vol%. Selectatec®, With interlocking function. Vaporizer types: Halothane, Enflurane, Isoflurane and Sevoflurane. |
|
| O2 cell | Standard | |
| Built-in Heater | Standard | |
| By-pass | Standard | |
| ACGO | Standard | |
| Li-ion Battery | Standard 1 battery 4400mAh (optional 6600mAh) | |
| Spare Cylinder yoke | Optional (O2, N2O) | |
| AGSS | Optional | |
| Gas monitor module | Optional (ETCO2, AG) | |
| Patient monitor | Optional | |
| Suction Device | Optional | |
| Standard: Main unit, one Isoflurane vaporizer, O2 cell, Built-in Li-on battery, Disposable adult anesthesia breathing circuit, O2/N2O/Air gas pipelines, Hospital O2/N2O/Air joints | ||
| Options: Extra vaporizer, Patient monitor, ETCO2, Suction module, Pediatric/Neonate anesthesia breathing circuit, Spare cylinder yoke (O2, N2O), AGSS, Gas monitor module (ETCO2, AG), etc. | ||