| Classification | Item | Parameter |
| Measuring range | Corneal diopter(K) | 36.21-50.60D |
| Astigmatism (AST) | 0°-180° | |
| Axial length (AL) | 14~33mm | |
| White to white (WTW) | 7~16mm | |
| Pupil diameter (PD) | 2~13mm | |
| Repeatability | Corneal diopter(K) | ≤0.13D |
| Astigmatism (AST) | ≤2° | |
| Axial length (AL) | ≤0.025mm | |
| White to white (WTW) | ≤0.3mm | |
| Pupil diameter (PD) | ≤0.3mm | |
| Others parameter | Power | up to 220VA |
| Voltage | a.c.220V | |
| Frequency | 50Hz | |
| AL-VIEW lite | ||
| Eye Axial Length View | ||
| An intelligent assistance for myopia screening and preventing among teenager
AL-VIEW LITE is an optical biometer based on optical low-coherence reflectometry technology (OLCR) with one time non-contact measurement. It present multiple bio parameters of eye, including axial length, corneal curvature,etc. With intelligent operation, AL-VIEW LITE enhance examination efficiency and reducing labor costs, which is an ideal tool for screening myopia in teenagers |
||
| High-speed and full automatic | ||
| The entire process is automated. Examinee only need to place the chin on the chin-rest and forehead tightly against it. Al-view lite will automatically search eye, focus, measure and then change eye position. The measurement is seamless and particularly suitable for large-scale population screening. | ||
| Non-contact examination comfort and safety | ||
| Based on optical measurement principle, it is completely non-contact cornea , avoiding risk of cross-infection and corneal injury. | ||
| Intelligent analysis report | ||
| Al-view lite ,based on authoritative date reference, intelligently analyse each test parameter, customize personalized analysis reports for examinee, and provide feasible suggestion . it is an excellent assistance for preventing myopia in teenagers and managing eye health. | ||
| Concentrate myopia control | ||
| l focus on eye health
l myopia control l establish eye health management record, conduct regular monitoring of eye axial development l provide objective assessment date for effectiveness of myopia control l quantify index, convenient follow up l intelligent operation, rapid measurement, suitable for large-scale screening |
||
| Eye health management | ||
| l help to detect cause and type of myopia, guide most effective clinic prevention and strategy
l risk assessment of eye diseases l excessive corneal curvature, alert of keratoconus l shallow anterior chamber depth, awareness of angle-closure glaucoma l excessive eye axial length, attention to retinal degeneration |
||
| one measurement obtain 10 parameters accuracy and reliability | ||