Products

ARX-2200

Digital C-arm X-ray System

Features

-Simple structure, highly integrated, no external drag cable, easy to use,

-Large anode heat capacity to support long-term use,

-High Ma pulse does not worry about the unclear body position image of obesity,

-Excellent image algorithm without dynamic tailing,

-AK & AKR dynamic monitoring; Real time dose display; High dose prompt; Over dose suspension exposure,

-50KW high power; Original BDG timing interconnected image acquisition.


Product performance and parameters

Project

Model

Features and Performance

High Voltage Generator

DTXR-50HF

Power: 50KW;

Photograph tube current: 10mA-630mA;

Continuous fluoroscopy tube current: 0.5mA-6mA;

Pulse fluoroscopy tube current: 1mA-80mA;

Exposure current time product 0.1mAs-630mAs;

Photograph tube voltage:40kV-150kV;

Fluoroscopy tube voltage 40kV-125kV;

Can be directly connected to the network cable and remote control for fault judgment and maintenance.

X-ray tube

E7884X

CANON

Dual focus 0.6mm/1.2mm;

Power 20 / 50KW;

Maximum current 700mA;

Maximum photography voltage 150kV;

Maximum fluoroscopy voltage 125kV;

Target angle 12°: permanent filtration 0.9 mm Al / 75KV;

Anode heat capacity 210KJ(300khu).

High voltage cable

75KV-3M

Withstand voltage: 75KV;

Length: 3m.

Mobile C-arm rack

CZJ

The sliding angle of C-arm along the arc track of arm support is 110°;

The rotation angle of C-arm along the horizontal axis is ± 180°;

The range of C-arm moving up and down along the vertical direction is 350mm;

Sid: 1000mm;

Maximum vertical depth from X-ray center to arc wall of C-arm: 500mm;

Minimum distance from X-ray source assembly shell to image receiver: 800mm;

Mobile performance:

a) The braking force of the C-arm on the flat cement ground is not less than 200N;

b) The starting push (pull) force is not more than 250N while the C-arm is on the flat cement ground.

c) Sports protection: Mechanical foot brake.

Flat Panel Detector

560RF

Caesium iodide amorphous silicon panel;

Pixel matrix: 1536x1536pixels;

Imaging area: 236mmx236mm;

Pixel size: 154μm; spatial resolution: 3.3lp/mm;

AD conversion 16bits;

Maximum frame rate in various photography modes:13fps@1536 × 1536pixels , 30 fps@768 × 768pixels;

Dynamic range: > 80dB;

Imaging time: photography imaging time is not more than 5s, fluoroscopy imaging time is not more than 1s.

Image

acquisition

workstation

DRF

DICOM3.0 standard; the reference exposure parameters of each position can be directly called out from the software for doctors to adjust the exposure parameters of the high voltage generator panel for reference;

Digital photography function, configurable positive and negative image acquisition;

Digital real-time fluoroscopy function: real-time automatic window width and window level adjustment; real-time edge enhancement: flip and rotate according to different positions; display patient information /examination information /settings Standby information /image information; real time prompt the number of images that the system can store;real time automatic ROI clipping.

Under the highest pulse fluoroscopy frame rate, fluoroscopy: image stability time is not more than 2s; automatic fluoroscopy function, image brightness stability is not more than 15%; photography under the maximum field of vision: 75KV, 80mA,5mAs, the number of discernible dynamic wedges is not less than 16;

Under the maximum field of vision fluoroscopy: 50kV, 3mA, discernable dynamic order wedge number is not less than 15; the maximum fluoroscopy image acquisition rate should not be less than 25 frames/s.

Hardware configuration:

CPU: i5-7500 or above; Memory: 4G or above;

Graphics card: GPU NVIDIA Geforce GTX 750ti /p620 (GPU computing power above 5.0)

Hard disk: 1 T;

Motherboard: 1 graphics card slot 1 pci- exi6 /pci-ex4 or gigabit network card;

Operating Display: 1600 * 1200 resolution;

System software: windows7, windows10 (64 bit)

Grid

10*10

The grating ratio is 10:1; 40lp / cm; the size is 25 * 25cm.

Collimator

 XSQ-C

Fixed type.

Dose monitoring device

2011

DAP; AK; AKR dynamic monitoring; real-time display; high dose prompt; over dose termination of exposure.

Professional Diagnostic Display

ML2002

Size: 21.3"; Type: Monochrome;

Mpixel:2MP; Resolution: 1600x1200;

Max Brightness: 1900cd/m2; Grayscale tone:16bit.

Remote Box

 

Can be remote controlled tube stand and photography frame, suitable for large-size chest X-ray examination

Operation display

 

Size: 19";

Brand: Dell



Copyright © 2001-2024 ARI Medical Technology Co., Ltd. - ARI Technology Group Co., Ltd. All Rights Reserved.