Your position:Home> Products>X-ray Series>CT

Products

OCT-D60

Optical Coherence Tomography

Features

OCT-D60 uses LSLO technology, with up to 3.5mm scan depth, and the lateral resolution of retinal fundus image is up to 5 um. Equipped with professional analysis software, OCT-D60 can obviously show the macular thickness under the macular thickness analysis model, which helps accurately identify clinical macular diseases.

Deep to the Bottom of Fundus

The scan depth is up to 3.5mm, reaching to the choroid and even the sclera. Fully display of all layers during one scan. The scan depth (imaging depth) is one of the most important performance parameters in the OCT system. OCT-D60 has an obvious advantage in depth, that is, the choroid imaging is clearer without affecting the axial resolution. It has significant advantages for funds diseases involving high depth and high resolution, such as choroid disease diagnosis.

Wide to the Edge of Vision

Large scanning range, clear macular and optic disc area at a glance.

Auto Focus

OCT-D60 can automatically complete the tracking of fundus and macula, detect and calibrate the central part of the pupil, detect and adjust the focus and fault position, and display retina layers of high-definition. The whole acquiring time is limited to 5 seconds, greatly saving the diagnosis time for

Scan mode

OCT-D60 has a variety of scan modes, including area scan, HD one line scan and multilines scan.

Area scan: 512*64, range 6mm*6mm\range 12mm*12mm

HD one line scan: 2048*30, length 6mm; 1024*30, length 12mm Multilines scan: 5 lines parallel scan, Radiation scan, Circular scan

Glaucoma Analysis

Accurately measure the retinal thickness around the fovea and compare

It with the age-related normal date to analyze the deviation of

Perform circular scan around the optic papilla, automatically quantify the optic nerve thickness, and compare the thickness with database, so as to examine the atrophy of the optic nerve as an early sign of glauco-ma.

Follow-up, a More Efficient Patient Management

Accurate and rapid scan helps follow up the disease changes, making diagnosis more efficient and easier.

OCT-D60 can automatically record current scanning position of macular and eyeball and intelligently locate the previous scanning position in the later follow-up examination, to ensure that two scans are in thaname position. Based on the trend analysis of retinal thickness in different stages, perform long-term follow-up examinations and trend analysis.

Anterior Segment Examination

Cornea scan

l  HD scan, multiple images combined to produce better image, clear cornea structure

l  Auto measurement and manual measurement for each cornea layer thickness

Technical Specifications

PARAMETER

SPECIFICATION

Scan light source

Central wavelength: 843nm

Maximum scanning depth: 3.5mm

Scanning range: 13mm x13mm

Light power: ≤750 μw (at the cornea)

Refractive compensation range: -20D~+20D

Resolution (Optic)

Axial resolution: 5 μm

Horizontal resolution: 13 μm

Fundus image

Linear scanning ophthalmoscope (LSO)

Central wavelength: 780nm

Maximum imaging range: 45.0° ×45.0°

Scan mode

Scans the area: 6mm X6mm, 12mm X12mm

Multi-line scan: five-line scan, radial scan, scan length 6mm/12mm

High list line scan: 6mm/12mm

Ring scan: diameter 3.5mm

Analysis functions

Macular thickness analysis, optic disc RNFL thickness analysis, follow-up analysis Anterior segment analysis: corneal thickness and atrial Angle were measured

PC

Hard disc: 2T

CPU: 17-8700

GPU: Intel 630 (128MB/ Engine)

RAM:16GB

Display: 24-inch LCD screen

Standard configure

Coherence Tomography, Computer, Keyboard, mouse, Monitor, Elevate table



Copyright © 2001-2024 ARI Medical Technology Co., Ltd. - ARI Technology Group Co., Ltd. All Rights Reserved.